MasterFormat® 2016, a product of the Construction Specifications Institute (CSI), is a widely used standard for documenting project requirements on commercial and institutional building projects in the United States and Canada. The MasterFormat is organized by divisions and sections. Each division addresses a different set of requirements for the construction project. Division 27 specifically addresses communications construction, providing specifications and instructions for areas such as data, voice, audio, video, cabling, enclosures, grounding and bonding. Division 26 addresses electrical construction and covers areas such as cable tray and industrial enclosures. How to Use CPI's Product Specifications The links below provide reference specifications for CPI products under Division 27 and 26. There are also hidden specifiers notes to assist in product selection. Download the files that you need and modify them to match your specific requirements. CPI also offers BIM Revit drawings on the CPI website or the bimobject® website (formerly Autodesk Seek) including models that make creating runway and tray pathways easy, as well as aisle containment doors and ducts. Section 27 05 26: Grounding and Bonding for Communications Systems This document provides minimum composition requirements and installation methods for the following: Primary Busbar (PBB) Secondary Busbar (SBB) Rack Busbar (RBB) Bonding Jumpers and Straps Compression Lugs Compression Taps Pedestal Clamps Pipe Clamps Antioxidant Joint Compound Click here to download. Section 27 11 16: Communications Cabinets, Racks, Frames and Enclosures These documents provide minimum composition requirements and installation methods for the following: ZetaFrame™ Cabinet System Thermal Management Accessories Cable Management Accessories Power Management Accessories Environmental Monitoring For Cabinets CUBE-iT™ Cabinet System ThinLine II Wall-Mount Cabinet Standard Wall-Mount Cabinet Hot and Cold Aisle Containment Enclosures (HAC/CAC) Rack Systems Consolidation Point Enclosures Telecommunications Enclosures Wireless Enclosures Click here to download. Section 27 11 23: Cable Management and Ladder Rack This document provides minimum composition requirements and installation methods for the following: Vertical Cable Management for Rack Systems Horizontal Cable Management for Rack Systems Ladder Rack (Cable Runway) Click here to download. Section 27 11 26: Communications Rack Mounted Power Protection and Power Strips This document provides minimum composition requirements and installation methods for the following: Rack-Mounted Power Distribution Units Click here to download. Section 26 27 16: Electrical Cabinets and Enclosures This document provides minimum composition requirements and installation methods for the following: RMR Fixed Wall-Mounted Enclosure. RMR Swing Wall-Mounted Enclosure. RMR Floor-Mount Enclosures RMR Free-Standing Enclosures RMR Standard Wall-Mount Enclosures RMR Flange-Mount Disconnect Enclosures Click here to download. Section 27 21 33: Data Communications Wireless Access Points This document provides minimum composition requirements and installation methods for the following: In-Plane™ - Panel, Suspended and Hard Ceiling Recess Mounts H-Plane™ - Open Ceiling and Right-Angle Wall Mounts Hi-Bar™ - Wall and Hard-Ceiling Surface Mounts M-Frame™ - Modular Wireless Mounting Platform Skybar™ - Outdoor and Public Venue Access Point Enclosures Wi-Tile™ - Suspended and Hard Ceiling Locking Enclosures NetPoint™ - Wireless Bollards For Outdoor and Public Venues Retrofit Doors and Trims – Replacement Doors and Trims AP Covers – Vanity Covers for Existing Products Click here to download.